This document discusses how async lines are numbered in Cisco 3600 Series Routers.
There are no specific requirements for this document.
The information provided in this document is not restricted to any specific software version, and is based on the hardware platform below:
- Cisco 3600 Series Routers
The information presented in this document was created from devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If you are working in a live network, ensure that you understand the potential impact of any command before using it.
For more information on document conventions, see the Cisco Technical Tips Conventions.
Async lines are not numbered in a linear fashion on the Cisco 3600 platform. Due to the modular design of these routers, there are fixed line ranges for each slot and each slot is allocated 32 line numbers. This means that the configuration does not change when you add or remove async lines from other slots. The following table shows the reserved line numbering per slot on Cisco 3600 router platforms.
Slot Platform Reserved line numbering
0 3620/3640 1-32
1 3620/3640/3660 33-64
2 3640/3660 65-96
3 3640/3660 97-128
4 3660 129-160
5 3660 160-192
6 3660 193-224
Important :Slot 0 is reserved for the motherboard on the Cisco 3660. This slot cannot hold any network modules; therefore, line numbering on the Cisco 3660 starts at 33, corresponding to the numbering associated with slot 1 for the whole Cisco 3600 family. For sample configurations refer to the 3600 Product Support Page.
The following diagrams illustrate the positions of the various slots on Cisco 3620, 3640, and 3660 routers:
Cisco 3620
Cisco 3640
Cisco 3660
Modules with async ports have different densities (for example, 4, 16, 24, and so on). It is possible to have a combination of network modules with several line ranges that have gaps in their numbering. If the same functionality is desired for all async lines, you have to replicate the configuration in all line ranges. Be careful when using line range commands such as the group-range command under Group-Async interfaces. This command does not allow discontiguous range configuration; therefore, you need separate Group-Async interfaces so that each of them references a separate line range.
Following is a sample hardware configuration:
Chassis: Cisco 3660
Slot 1: NM-4A/S (4 Port Sync/Async Serial Network Module)
Slot 2: NM-4A/S (4 Port Sync/Async Serial Network Module)
Slot 3: Empty
Slot 4: NM-32A (32 Port Async Network Module)
Slot 5: Empty
Slot 6: Empty
After the router boots up, here are the default line ranges:
c3660#show running-config | begin line con 0
......
line con 0
transport input none
line 33 36
line 65 68
line 129 160
line aux 0
line vty 0 4
login
!
end
The modules are rearranged in this configuration:
Slot 1: NM-32A (32 Port Async Network Module)
Slot 2: NM-4A/S (4 Port Sync/Async Serial Network Module)
Slot 3: Empty
Slot 4: Empty
Slot 5: Empty
Slot 6: NM-4A/S (4 Port Sync/Async Serial Network Module)
When the modules are rearranged, these are the default line ranges:
c3660#show running-config | begin line con 0
line con 0
transport input none
line 33 68
line 193 196
line aux 0
line vty 0 4
login
!
end
No comments:
Post a Comment